Round Plastic Shell IP20, Triac Dimmable Driver, High PF>0.95, 5 year warranty
● Constant voltage output,50/60Hz
● Plastic case,Class II, IP20
● Built-in EMI filter with tiny ripple,flicker-free
● High performace and reliability
● Typical lifetime ≥ 50000 hours
● 100% full load bur-in test
● Protection: Short circuit/Over voltage/Over load
● 5 years warranty
Model | Power | Input Voltage | Output Voltage | Output Current | Efficiency | PF | Dimension | Weight | Warranty |
NC-12020-LVT2 | 20W | 90-130V/ 200-240V | 12V | 1.67A | ≥84% | ≥0.9 | D67*20mm | 70g | 5 years |
NC-24020-LVT2 | 24V | 0.83A | |||||||
NC-36020-LVT2 | 36V | 0.56A | |||||||
NC-48020-LVT2 | 48V | 0.42A | |||||||
NC-12030-LVT2 | 30W | 90-130V/ 200-240V | 12V | 2.50A | ≥85% | ≥0.9 | D73*27mm | 100g | 5 years |
NC-24030-LVT2 | 24V | 1.25A | |||||||
NC-36030-LVT2 | 36V | 0.83A | |||||||
NC-48030-LVT2 | 48V | 0.63A | |||||||
NC-12040-LVT2 | 40W | 90-130V/ 200-240V | 12V | 3.33A | ≥85% | ≥0.9 | D78*31mm | 150g | 5 years |
NC-24040-LVT2 | 24V | 1.67A | |||||||
NC-36040-LVT2 | 36V | 1.11A | |||||||
NC-48040-LVT2 | 48V | 0.83A | |||||||
NC-12060-LV2 | 60W | 90-130V/ 200-240V | 12V | 5.00A | ≥86% | ≥0.9 | D102*31mm | 220g | 5 years |
NC-24060-LVT2 | 24V | 2.50A | |||||||
NC-36060-LVT2 | 36V | 1.67A | |||||||
NC-48060-LVT2 | 48V | 1.25A | |||||||
NC-12080-LVT2 | 80W | 90-130V/ 200-240V | 12V | 6.67A | ≥87% | ≥0.9 | D102*31mm | 230g | 5 years |
NC-24080-LVT2 | 24V | 3.33A | |||||||
NC-36080-LVT2 | 36V | 2.22A | |||||||
NC-48080-LVT2 | 48V | 1.67A |
Characteristics | Frequency | 50/60Hz | ||||||||
Voltage tolerance | ±5% | |||||||||
Max Load | 80% | |||||||||
Inrush Current((A ) | <50A | |||||||||
Ripple&noise | <200mVP-P | |||||||||
hold-up/start-up time time | 100ms, 30ms,20ms/ 230VAC | |||||||||
Leakage current((mA ) | <0.5mA / 230VAC | |||||||||
Protection | Over current | above 108%-116%,power limiting, recovers automatically after fault removed | ||||||||
Over voltage | switch off, recovers automatically after fault removed | |||||||||
Short circuit | hiccup mode,recovers automatically after fault removed | |||||||||
Environment | Operating Temperature | ‘-25℃~~+50℃ | ||||||||
Storage Temperature | ‘-30℃~~+80℃ | |||||||||
Humidity | 20~~95% | |||||||||
Security | LVD | 2014/35/EU | ||||||||
EMC | 2014/30/EU | |||||||||
Voltage Insulation/Isolation Resistance | I/P-O/P:3.75KVAC,I/P-O/P:>100M Ohms/500VDC/28℃/68% RH | |||||||||
Classification of Installation and Use | Class I | |||||||||
Note | ◊ All parameters NOT specially mentioned are measured at 240VAC input, max rated load and 25℃ of ambient temperature | |||||||||
◊ Ripple & Noise are measured at 20MHz of bandwidth by using a 300mm twisted pair-wire terminated with a 0.1uF & 47 uF parallel capacitor. | ||||||||||
◊ The driver is considered as a component to be operated in combination with equipment,since performance will be affected by the complete installation. | ||||||||||
◊ Good heat dissipation will prolong the working life of the driver.Please ensure good ventilation. | ||||||||||
◊ Please check if the output voltage/current of any LED lights used comply with the working voltage/current of the product. | ||||||||||
◊ Be ware of high power pressure may caused by short circut when installing metal casing products. | ||||||||||
◊ Please ensure all wires connections and polarities are correct before appling power to avoid any damages to LED Lights. | ||||||||||
◊ The product shall be installed and serviced by a qualified person. | ||||||||||
◊ Please contact supplier if a fault occurs. |
(Unit:cm)