Constant Voltage TRIAC&0-10V / DALI Dimmable Driver IP20
● Constant voltage output,50/60Hz
● Aluminum case with cable,Class I, IP67
● Built-in EMI filter with tiny ripple,flicker-free
● High performace and reliability
● Typical lifetime ≥ 50000 hours
● 100% full load bur-in test
● Protection: Short circuit/Over voltage/Over load
● 2 years warranty
Model | Power | Input Voltage | Output Voltage | Output Current | Efficiency | PF | Dimension | Weight | Warranty |
NC-12060-TOS | 60W | 180-260Vac | 12V | 5A | >83% | >0.6 | 180*50*30mm | 320g | 2 years |
NC-24060-TOS | 24V | 2.5A | |||||||
NC-12080-TOS | 80W | 180-260Vac | 12V | 6.6A | >83% | >0.6 | 180*50*30mm | 330g | 2 years |
NC-24080-TOS | 24V | 3.3A | |||||||
NC-12100-TOS | 100W | 180-260Vac | 12V | 8.3A | >85% | >0.6 | 230*50*30mm | 350g | 2 years |
NC-24100-TOS | 24V | 4.2A | |||||||
NC-12120-TOS | 120W | 180-260Vac | 12V | 10A | >85% | >0.6 | 230*50*30mm | 360g | 2 years |
NC-24120-TOS | 24V | 5A | |||||||
NC-12150-TOS | 150W | 180-260Vac | 12V | 12A | >87% | >0.6 | 287*50*30mm | 480g | 2 years |
NC-24150-TOS | 24V | 6A | |||||||
NC-12200-TOS | 200W | 180-260Vac | 12V | 16A | >88% | >0.6 | 287*50*30mm | 490g | 2 years |
NC-24200-TOS | 24V | 8A | |||||||
NC-12250-TOS | 250W | 180-260Vac | 12V | 20A | >89% | >0.6 | 287*50*30mm | 500g | 2 years |
NC-24250-TOS | 24V | 10A | |||||||
NC-12300-TOS | 300W | 180-260Vac | 12V | 25A | >90% | >0.6 | 295*60*30mm | 550g | 2 years |
NC-24300-TOS | 24V | 12A | |||||||
NC-12350-TOS | 350W | 180-260Vac | 12V | 29A | >90% | >0.6 | 295*60*30mm | 630g | 2 years |
NC-24350-TOS | 24V | 14A | |||||||
NC-12400-TOS | 400W | 180-260Vac | 12V | 33A | >90% | >0.6 | 295*60*30mm | 650g | 2 years |
NC-24400-TOS | 24V | 16A |
Characteristics | Frequency | 50/60Hz | ||||||||
Voltage tolerance | ±5% | |||||||||
Max Load | 80% | |||||||||
Inrush Current((A ) | <50A | |||||||||
Ripple&noise | <200mVP-P | |||||||||
hold-up/start-up time time | 100ms, 30ms,20ms/ 230VAC | |||||||||
Leakage current((mA ) | <0.5mA / 230VAC | |||||||||
Protection | Over current | above 108%-116%,power limiting, recovers automatically after fault removed | ||||||||
Over voltage | switch off, recovers automatically after fault removed | |||||||||
Short circuit | hiccup mode,recovers automatically after fault removed | |||||||||
Environment | Operating Temperature | ‘-25℃~~+50℃ | ||||||||
Storage Temperature | ‘-30℃~~+80℃ | |||||||||
Humidity | 20~~95% | |||||||||
Security | LVD | 2014/35/EU,EN61347-1:2015,EN61347-2-13:2014 | ||||||||
EMC | 2014/30/EU,EN55015:2013+A1:2015, EN61547:2009,EN61000-3-2,EN61000-3-3:2013 | |||||||||
Voltage Insulation/Isolation Resistance | I/P-O/P:3.75KVAC,I/P-O/P:>100M Ohms/500VDC/28℃/68% RH | |||||||||
Classification of Installation and Use | Class I | |||||||||
Note | ◊ All parameters NOT specially mentioned are measured at 240VAC input, max rated load and 25℃ of ambient temperature | |||||||||
◊ Ripple & Noise are measured at 20MHz of bandwidth by using a 300mm twisted pair-wire terminated with a 0.1uF & 47 uF parallel capacitor. | ||||||||||
◊ The driver is considered as a component to be operated in combination with equipment,since performance will be affected by the complete installation. | ||||||||||
◊ Good heat dissipation will prolong the working life of the driver.Please ensure good ventilation. | ||||||||||
◊ Please check if the output voltage/current of any LED lights used comply with the working voltage/current of the product. | ||||||||||
◊ Be ware of high power pressure may caused by short circut when installing metal casing products. | ||||||||||
◊ Please ensure all wires connections and polarities are correct before appling power to avoid any damages to LED Lights. | ||||||||||
◊ The product shall be installed and serviced by a qualified person. | ||||||||||
◊ Please contact supplier if a fault occurs. |
(Unit:cm)